The connecting cable provides electrical power to the entire system. Viewed 72k times. You can find very efficient models available in both 115 and 220 volts. How to wire a 220V power plug? Measure the shortest route between the outlet box and your circuit breaker, then cut a 10/4 cable so that its 2-3 feet (61-91 cm) longer than the distance you measured. Only allow a certified electrician to take care of that job. Then it would depend on whether the indoor unit uses a 120v blower. You guys are wonderfulhere's the nameplate: Voltage: 208/230VPhase: 1Hertz: 60Total Amps: 19.4Compressor Amps: R.L.A. If the 220 line goes through the floor, then you must also install conduit through the floor. 5 years warranty on compressor and 2 years on parts The General Recommendation Is A 20A Circuit Breaker And 12 Awg (Or Larger Wiring). The EZ-IN cable contains 4 THHN wires, are shielded with MC and rated for outdoor use. The Mini Split AC/Heat Pump is becoming the method of choice for heating and cooling home additions, workshops, and garages, just to name a few places popular for installation. To meet the code, you must have a shut-off box at the location of the unit. These wires are to be run all the way from the main panel to a disconnect box on the outside of the building within just a few feet of where the outdoor unit will be located. Mr Cool Mini Split Wiring Diagram - Wiring Diagram Schemas wiringschemas.blogspot.com. What size breaker for 24,000 BTU mini split? If you need to cut through concrete or brick, use a drill with a masonry bit so you dont cause any damage to the tool or chip the wall. The AC electrical voltage will be 110-120 or 220-230 Volts. Screw a wall plate over the outlet to hide the inside of the outlet box and wires. As most know, this is what a breaker does it shuts off, stopping the flow of power if there is a problem. Run a rigid metal electrical conduit from the side of the breaker box to the hole you drilled and attach it to the wall with conduit straps every 1-2 feet (30-61 cm). A few more might start a fire, whether you're there or not. The AC electrical voltage will be 110-120 or 220-230 Volts. This post is meant to give the basics of wiring up a mini split. Mini-Split Parts & Accessories . 1.5, HP 0.25Minimun Circuitry Ampacity (Amps): 23.9. He holds an HVAC associate degree from Lone Star College and EPA & R-410A Certifications. Installing a Solid Base for the Outdoor Unit A solid mounting area is needed for the outdoor unit. It sucks because I already buried the line in conduit. The white wire should be marked black at the unit to indicate it is NOT a neutral but a hot. The end of the tool can be used to grip and bend wire which is handy for attaching wire onto the screw terminals of switches and outlets.. Do you need to know the recommended 12000 BTU mini split circuit breaker size? It uses this mainly for motor controllers ( SDB-075A2 ), some relays and motors. $251.99 . Wiring up a mini split HVAC unit is not difficult but does require some basic electrical knowledge. An Alternating Current 220v circuit works in a way where the Black wire gets power for half a cycle, then when that power cycle/phase ends the Red wire gets power for half a cycle when the Black wire is dormant. The best long term solution will be to run the 14/3 from the box to the unit. However, a good rule of thumb is 1 outlet per 1.5 amps, up to 80% of the capacity of the circuit breaker. Step 4: Screw and secure the two hot wires in the breaker but avoid . 125' Stranded Mini-Split Communication Wire - Non-Shielded (600 Volt) $159.99. For 12k MrCool you need standard 110/120V but for 18k, 24k, and 36k units you will need 220/240V. Get 2 hot wires from 2 different phases along with a ground wire, which must connect to the properly-identified terminals. System Cost Generally speaking, a 220v mini split will cost more than a 110v system of the same brand, BTU, and SEER. The owner of this website, hvachowto.com, is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking hvachowto.com to Amazon properties. The main goal of the conduit is to protect the wire from the elements. Did you mean 22.0 possibly? Typically if it's 220 v though it's going to be 12k btu+. This image may not be used by other entities without the express written consent of wikiHow, Inc.
\n<\/p>
\n<\/p><\/div>"}, {"smallUrl":"https:\/\/www.wikihow.com\/images\/thumb\/3\/3e\/Wire-a-220-Outlet-Step-8-Version-3.jpg\/v4-460px-Wire-a-220-Outlet-Step-8-Version-3.jpg","bigUrl":"\/images\/thumb\/3\/3e\/Wire-a-220-Outlet-Step-8-Version-3.jpg\/aid1456303-v4-728px-Wire-a-220-Outlet-Step-8-Version-3.jpg","smallWidth":460,"smallHeight":345,"bigWidth":728,"bigHeight":546,"licensing":"
\u00a9 2023 wikiHow, Inc. All rights reserved. Most HVAC companies will install a breaker with the correct amps and run a new line to the disconnect. A disconnect is just a manual shut off not a breaker. This image is not<\/b> licensed under the Creative Commons license applied to text content and some other images posted to the wikiHow website. 200Amp Mini MIG Welder 110V 2 in 1 MIG MMA/ARC Welding Machine IGBT W/Helmet US . What is 14 4 wire for mini split systems? Free shipping . Make sure the breaker is off before you install it. Rated Voltage : 220V Power Supply : AC Display Type : Cloud&APP Dimensions : 90.2*71*57.5mm (2 DIN pole) Model Number : WEM3080T Phase : Three Phase Operating Temperature : -20 - 60 Accuracy Class : Class 1 Max Operating Current : 150A & Above Communication : Wi-Fi CT Diammeter : 24.5mm Key Feature 1. I would try and tie in the 2 additional wall recepicles to one of the circuits dedicated to wall recepicles. Installation Cost a 220v mini split will require an additional circuit breaker and more expensive wiring than a 110v mini split. This image may not be used by other entities without the express written consent of wikiHow, Inc.
\n<\/p>
\n<\/p><\/div>"}, {"smallUrl":"https:\/\/www.wikihow.com\/images\/thumb\/2\/2e\/Wire-a-220-Outlet-Step-5-Version-3.jpg\/v4-460px-Wire-a-220-Outlet-Step-5-Version-3.jpg","bigUrl":"\/images\/thumb\/2\/2e\/Wire-a-220-Outlet-Step-5-Version-3.jpg\/aid1456303-v4-728px-Wire-a-220-Outlet-Step-5-Version-3.jpg","smallWidth":460,"smallHeight":345,"bigWidth":728,"bigHeight":546,"licensing":"
\u00a9 2023 wikiHow, Inc. All rights reserved. A Mini Air Conditioning Unit only needs one 220v 30 amp disconnect. This image is not<\/b> licensed under the Creative Commons license applied to text content and some other images posted to the wikiHow website. IIRC, new code does not allow this type of installation (for appliances). L1 and L2 are connected to the same polarity of a single phase service. It runs happily. Great Unit!!!! A wrap of black electrical tape is fine.It should also be marked at the breaker (and any other boxes it passes through) but that is not as important.Anyone working in the panel will instantly know it is a hot since it will be hooked to the breaker.At the unit this is not as readily apparent. Wrap the ends of the white and green wires around separate screws on the grounding bar in your circuit box and secure them in place by tightening the screws. This is because it requires a high level of electricity that is only accessible through the panel. Step 3: Insert each 220v wire into the right receptacle in the two-pole circuit breaker. The breaker will need the correct amps the mini split is rated for and will be displayed on the breaker. What home projects will you tackle in 2017? You connected two hots and neutral but no ground. I need to replace everything and cant find where to get the parts at all.. wikiHow, Inc. is the copyright holder of this image under U.S. and international copyright laws. outside hole. Example Electrical Whip on Amazon Advice appriciatedMike in Mayberry. A 220 circuit uses less amps than a 110. If you dont want to fish the cable through your walls, you can also attach metal conduits to your wall and feed the cable through it instead. While a 110v system only needs two wires to conduct the electricity, a 220v system requires three. Daniel Stoescu is a Master Electrician and the Owner and Operator of Home Tech Solutions, LLC in Hampton, Virginia. It doesnt matter which unlabeled screw the red or black wire is attached to since they both will carry the same current to the outlet. wikiHow, Inc. is the copyright holder of this image under U.S. and international copyright laws. A 110V mini split will typically require a thicker wire due to the lower voltage, while a 220V unit will require a thinner wire to handle the higher voltage. This image is not<\/b> licensed under the Creative Commons license applied to text content and some other images posted to the wikiHow website. I go over How to Connect the Power Wires from the Disconnect to the Outdoor Unit after Installing the Whip. You should be using a Chapter 3 wiring method between the units. Now the A/C works (I do not need the heat pump to function). Step 5; Secure the black and red wires into the two unlabeled slots. Best DIY Mini Split Heat Pumps that Cools and Heats, 9 Tips and Tricks for DIY Mini Split Installations, Ductless Mini Split Buyer Frequently Asked Questions FAQ, Overview of KWIK-E-VAC Line Set Flushing Kit and How To Use. That said, Ive seen 12/2 wire on 30AMPS breaker in old houses and nothing bad happened; the new standards are just very very conservative. Installing 220 Volt Outlet www.chanish.org 12000 Btu Mini Split Air Conditioner/Heat Seer 20 Inverter $660 -. A disconnect box is simply a junction that, like a switch, turns on and off the power when needed. The Home Tech Solutions team has over four decades of combined experience and offers comprehensive solutions for residential electrical needs. A steady one amp will kill you. You may also use 8-gauge wires if for your 220 outlet if you want. 21 June 2021. while, so I wanted to double check. How can I connect a four-wire 125/250 volt, 30 amp cable to a three-wire 220 volt, 30 amp outlet? $909.65 $791.00. This probably would not work. You connected the two hots and ground but not the neutral. Doing so could result in serious injury or death. This image may not be used by other entities without the express written consent of wikiHow, Inc.
\n<\/p>
\n<\/p><\/div>"}, {"smallUrl":"https:\/\/www.wikihow.com\/images\/thumb\/e\/ee\/Wire-a-220-Outlet-Step-19.jpg\/v4-460px-Wire-a-220-Outlet-Step-19.jpg","bigUrl":"\/images\/thumb\/e\/ee\/Wire-a-220-Outlet-Step-19.jpg\/aid1456303-v4-728px-Wire-a-220-Outlet-Step-19.jpg","smallWidth":460,"smallHeight":345,"bigWidth":728,"bigHeight":546,"licensing":"
\u00a9 2023 wikiHow, Inc. All rights reserved. This image may not be used by other entities without the express written consent of wikiHow, Inc.
\n<\/p>
\u00a9 2023 wikiHow, Inc. All rights reserved. The end of the tool can be used to grip and bend wire which is handy for attaching wire onto the screw terminals of switches and outlets.. The electrical code requires that the line voltage signal wires be protected from nails and youd want to do the same for the refrigerant lines and the drain line. If the branch circuit serves a 240v load there is no requirement to cable a neutral along just to cap it, but its the smart thing to do in case some replacement down the line does need it. A 220-volt circuit supplies twice the voltage of a standard one. If wikiHow has helped you, please consider a small contribution to support us in helping more readers like you. If you wish to submit it, click on the submit button.If you wish to make changes, you can either use your browser's "Back" button and return to the original form, or use the form at the bottom of this page. If the compressor is made for 120v power, L1 is the ungrounded (black) power conductor and L2 is the (white) grounded (neutral) power conductor. N 12 : 20 ampres, 120 volts, It is common to run 2-conductor plus ground cable. globe life field food menu 2021; is hare and tortoise halal. Is this okay? The additional ground wire is a safety measure to prevent a house fire or an electric shock if there is excess electricity in the wiring system. Required fields are marked *. Technically, you can have as many outlets on a 15 amp circuit breaker as you want. Most Mini Split units will have the inside and outside units marked with numbers 1, 2, 3, and ground which the wires color code will match. I'm looking to install a 4th Gen, DIY Mr Cool Mini Split in my home. --------------------------------------------------------------------------------, RE: 220V mini-split A/C wiring questionsPosted by mikeinmayberry (My Page) on Tue, Jun 22, 10 at 20:48, Let me try this againI'm working off of pictures 140 miles away from the unitsI fat fingered this the first timepulled the info off of the wrong picture.Ductless mini-splitModel S240HP-13K11-0Cooling Cap: 12500 BTUHeating Cap: 13000 BTUVoltage: 208V/240V1 PH/60 HZTotal Input Current: 6.22ACompressor RLA 5.7A, FLA 33AFan Motor Outside: 0.064 HP, .56AFan Motor Inside: 0.03HP, .16A. If so where can i buy one, all the boxes and whips are for 240v, A 240 volt disconnect will work with 120 volts, So I was dumb enough to wire up 240v to a 120v, I know I burned up the mother board. This image may not be used by other entities without the express written consent of wikiHow, Inc. \u00a9 2023 wikiHow, Inc. All rights reserved. Time needed: 2 days. Here is a link on Amazon 1/2-Inch Non-metallic Liquid Tight Straight Electrical Conduit Connector Fitting The amps it draws to run will also be rated. How many amps does a 12,000 BTU mini split use? Source: wiringdiagram.2bitboer.com Wire the mini split. Red is the common marking of the 2nd Load or power leg of a 220v circuit. If the conductor breaks or a splice fails it may be at line potential.). mamba f405 mk2 diatone controller 8k betaflight f25 25a mk3 20a flightcontroller 4in1 dshot600 fpv osd pinout vtx f722s schma. How To Wire Up a Mini Split Air Conditioner or Heat Pump. The holes of the receptacle, as well as the prongs on the plugs of appliances you use in these circuits, are configured differently so that you can identify them. When 220v wiring is used, less current is required than with 110v wiring. but it might. This image is not<\/b> licensed under the Creative Commons license applied to text content and some other images posted to the wikiHow website. Should I Use A 10/2 Or 10/3 Wire For A 220v Mini Split? SOLD JUN 15, 2022. Expert Interview. Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from any purchases after clicking through. If the panel is a main panel neutrals and grounds connect to the same bar. 9000 btu mini split air conditioner and heater brand : mirage model : ivkh090a seer : 20 inverter rate volt : 115 volt breaker size : 15 a refrigerant : 410 a brand new in the box (unopen box when. Interesting and good info. Make individual holes for drain line, refrigerant lines, and electrical cable, in that order from bottom to top. Tip: The ground wire inside the cable may be uninsulated rather than green. The hardware store only had a 30amp disconnect box (smallest) my unit is a 20 amp. Step 4. . (BTU to Sq Ft), Pros of Ductless Heating and Cooling Systems. Different brands of breakers snap into place in various ways, so check the instructions before you install it so you dont accidentally damage them. Did you just create a little crater (for lack of better term) in the wall for it to sit? This image is not<\/b> licensed under the Creative Commons license applied to text content and some other images posted to the wikiHow website. Here is a step-by-step procedure that a professional might do when installing a mini-split in your home: Step 1: Install A Disconnect Box To adhere to the code, installing a disconnect box is a requirement. Wiring a new 220 outlet is a project that someone who has experience working with electricity can do safely by working carefully and following the proper precautions. Most of the time, the conduit is run along a wall but can be buried or run through the walls of some homes. Over time the difference in thermal expansion and hardness will cause metal pipe thread in a pvc socket to loosen and leak. You would not mark the 2nd leg as a black, I would tape/mark it as red. With a ground wire connected to the enclosure, the fault current finds a low However, working on your circuit breaker box and electrical system can lead to serious injury or death if you dont know what youre doing, so hire an electrician if you aren't certain how to wire the outlet correctly. It is of monumental importance that the Red wire/leg be connected to a different Busbar in the Main Panel than the black wire, meaning the Black power/load is connected to other Busbar than the Red lead, There are 2 Busbars in every Main Panel. For some reason (that amounts to convenience) the same rule wasnt applied to wiring a switches to interrupt power to a load. I kind of knew myself, but it'd been a. The evaporator or air handler is the indoor unit. . As noted, all mini splits larger than 12000 BTUs use 220 power. 21st May 2022 / in stinging nettle new brunswick / by 12/2 wiring in conduit (I prefer flexible) If the compressor is made for 240v power, then the same polarity has been connected to both L1 and L2. All 18k btu and greater models require 220V. You can use a hole in the side of your circuit breaker box that already has wires running through it if theres room for your cable. Therefore, we would suggest a maximum of 8 outlets for a 15 amp circuit. My installation will have the inside blower mounted on an inside wall, and 8 feet to the left is the outside wall where the outside unit is mounted. The additional ground wire is a safety measure to prevent a house fire or an electric shock if there is excess electricity in the wiring system. Liquid Tight Conduit on Amazon I have been looking at a lot of information but am not able to confirm what I believe to be the required wiring for the system. This image is not<\/b> licensed under the Creative Commons license applied to text content and some other images posted to the wikiHow website. Also, I purchased some of the clamps that are in the above link and they seem to have a semi-sharp metal circle where yours appears to be smooth. 12000 btu mini split air conditioner and heater brand : mirage model : ivkh12a seer : 20 inverter rate volt : 115 volt breaker size : 15 a refrigerant : 410 a brand new in the box (unopen box when. Scenario 3: It requires two hots, neutral and ground. If you dont feel comfortable working on it, contact a professional electrician to wire the outlet for you. Free shipping . This image may not be used by other entities without the express written consent of wikiHow, Inc. \u00a9 2023 wikiHow, Inc. All rights reserved. However, you will still need ground as you can see. Scenario 2: It requires two hots, neutral and ground. Make sure you get a breaker that matches the circuit breaker box brand you have. Each one is 110 volts. No difference of potential therefore 0 volts. They specifically mention a bare ground wire. N 12 : 20 ampres, 240 volts DC control lines are included in most any good DIY mini split install package. Are there any 18,000 BTU mini split for 110 volt power? Typically 9k btu and 12k btu units are 110V. A 3-4 kW AC inverter is pretty big, and a good mini-split might be able use 1/2 or even less (some folks here using Mini-splits can set them on low and run ~300 watts all day long peak and average wattage to pre-cool/keep the house cooler during the day rather than having to run at 100% in the evening when everyone . 110V and 220V systems have different outlets. This image is not<\/b> licensed under the Creative Commons license applied to text content and some other images posted to the wikiHow website. First off, your central system requires 2-220v amp disconnects at 30 amps each. 4. Mini Split Power and Wire Size FAQs If it now has to supply a 240v load the cable will have to be pulled. This image may not be used by other entities without the express written consent of wikiHow, Inc. \u00a9 2023 wikiHow, Inc. All rights reserved. This could either be wire that is approved for outdoor use, or an electrical whip, which is a waterproof tube which looks somewhat like a garden hose through which wires are run. The normal configuration of the electrical connection for a mini split consists of the following: 1. This image may not be used by other entities without the express written consent of wikiHow, Inc. \u00a9 2023 wikiHow, Inc. All rights reserved.
\n<\/p><\/div>"}. You can see from the chart above that the answer is 14 amps. The condenser is the outdoor unit. This image is not<\/b> licensed under the Creative Commons license applied to text content and some other images posted to the wikiHow website. The rigid pipe will have to be installed in short segments with couplings between each stud. The straight 240 V setup is missing in the above examples. Strip the outer coating off of the last 1-2 feet (30-61 cm) of the end of the cable that will attach to the circuit box, then strip inch (1.3 cm) of insulation off of the ends of each of the wires. Example Disconnect Box on Amazon This makes system repairs safer and easier. wikiHow, Inc. is the copyright holder of this image under U.S. and international copyright laws. Sometimes a homes existing wiring can be tapped into and used depending on the scenario. Yes, you can run two 220v machines from a circuit, provided it does not exceed the degree of amplitude of the switch. For example, 12-gauge wire is thicker than 14-gauge wire. If the installation is a PVC drain pipe, Do not use the more easily found metal MPT to hose barb fittings use pvc if available, or nylon. recently had my roof re-done and they disconnected the wires from the unit on roof to the breaker box they connected the white neutral back to the correct slot on the breaker box but connected the black hot wire to the ground and know my unit wont turn on I disconnected the hot wire from the ground and connected to the correct This is commonly done using 2-conductor plus ground wire. If the 220v load exceeds 16 amps (80% of 20) and its considered a continuous load (operating for more than 3 consecutive. Thank you for choosing PREMIUM to conditioning your room. This tells us that the more cooling power a system has, the more electrical power it will require. I am installing a klimaire 2x9,000btu multi zone ductless mini split air conditioner (dc inverter). Im pretty sure I messed up. By signing up you are agreeing to receive emails according to our privacy policy. This post gives a basic overview of wiring up a mini split. $272.39 . Hence the current is alternating between the black and red wires. Wire the two hot leads to the fused connections in the box and the ground to the provided connection. What is this electrical whip? Pioneer Wyd Ductless Mini Split Systems Service Manual. Most all DIY mini split kits will come with the DC control line wiring. The top room has a "mini-split" heat pumpdarn thing wouldn't work. Outside shut off box adjacent to unit 17.9, L.R.A. This article focuses on the electrical connection that will provide the proper voltage and watts needed to power mini splits of different sizes. There is also a minor theoretical efficiency gain if you opt for the higher voltage, lower amperage system. Wiring the control lines is straightforward and easy enough by simply matching wires colors to the labeled numbers. Then from the cut off box to the outdoor unit I will need 12 gauge wire. Just connect the hot terminal and ground. Diy Mini Split Installation A Plete To Z Detailed Lrn2diy. Can you put 12-gauge wire on a 15 amp circuit? You can buy metal conduits from your local hardware store. Over 1,000 hours that's 9 kWh, or $1.30 of electricity at the average U.S. residential rate. I also show the EZ-IN outdoor connector. hey I bought a delta 18000 mini split heating and cooling pump Im putting outside a building which is wired from my house with a separate breaker box. The instructions that come with any unit should always be followed. New hereI like what I've seen so far. **** DAIZUKI Mini Splits COOL ONLY INVERTER 20 SEER Series **** With installation kit, Blue/Gold Fin Technology, Wi Fi ready or capable and precharged with Freon R410A, AHRI Certified, ETL/Intertek. {"smallUrl":"https:\/\/www.wikihow.com\/images\/thumb\/9\/93\/Wire-a-220-Outlet-Step-1-Version-3.jpg\/v4-460px-Wire-a-220-Outlet-Step-1-Version-3.jpg","bigUrl":"\/images\/thumb\/9\/93\/Wire-a-220-Outlet-Step-1-Version-3.jpg\/aid1456303-v4-728px-Wire-a-220-Outlet-Step-1-Version-3.jpg","smallWidth":460,"smallHeight":345,"bigWidth":728,"bigHeight":546,"licensing":"
\n<\/p>
\n<\/p><\/div>"}, {"smallUrl":"https:\/\/www.wikihow.com\/images\/thumb\/4\/48\/Wire-a-220-Outlet-Step-18.jpg\/v4-460px-Wire-a-220-Outlet-Step-18.jpg","bigUrl":"\/images\/thumb\/4\/48\/Wire-a-220-Outlet-Step-18.jpg\/aid1456303-v4-728px-Wire-a-220-Outlet-Step-18.jpg","smallWidth":460,"smallHeight":345,"bigWidth":728,"bigHeight":546,"licensing":"
\n<\/p>
\n<\/p><\/div>"}, {"smallUrl":"https:\/\/www.wikihow.com\/images\/thumb\/8\/8b\/Wire-a-220-Outlet-Step-7-Version-3.jpg\/v4-460px-Wire-a-220-Outlet-Step-7-Version-3.jpg","bigUrl":"\/images\/thumb\/8\/8b\/Wire-a-220-Outlet-Step-7-Version-3.jpg\/aid1456303-v4-728px-Wire-a-220-Outlet-Step-7-Version-3.jpg","smallWidth":460,"smallHeight":345,"bigWidth":728,"bigHeight":546,"licensing":"
\n<\/p>
\n<\/p><\/div>"}, {"smallUrl":"https:\/\/www.wikihow.com\/images\/thumb\/0\/07\/Wire-a-220-Outlet-Step-15.jpg\/v4-460px-Wire-a-220-Outlet-Step-15.jpg","bigUrl":"\/images\/thumb\/0\/07\/Wire-a-220-Outlet-Step-15.jpg\/aid1456303-v4-728px-Wire-a-220-Outlet-Step-15.jpg","smallWidth":460,"smallHeight":345,"bigWidth":728,"bigHeight":546,"licensing":"
\n<\/p>
\n<\/p><\/div>"}, {"smallUrl":"https:\/\/www.wikihow.com\/images\/thumb\/1\/15\/Wire-a-220-Outlet-Step-2-Version-2.jpg\/v4-460px-Wire-a-220-Outlet-Step-2-Version-2.jpg","bigUrl":"\/images\/thumb\/1\/15\/Wire-a-220-Outlet-Step-2-Version-2.jpg\/aid1456303-v4-728px-Wire-a-220-Outlet-Step-2-Version-2.jpg","smallWidth":460,"smallHeight":345,"bigWidth":728,"bigHeight":546,"licensing":"
Is Dr Michael Tompkins Married,
Straight Backed German Shepherd Breeders Uk,
Endeavor Air Pilot Contract,
Articles H